Emergency Checklist
Main Engine Failure
Version: 02 Issue: 17.10.2024
Reported to the Company
Oops...! some problem!
Immediate Actions
Call the Master
Exhibit “Not Under Command” signals
Consider anchoring if possible and safe to do so
Inform shipping in the vicinity
If relevant, inform VTS or other traffic service
Update AIS status
Secondary Actions
Inform the Company
Inform relevant local authorities
Monitor the situation, be aware that further action may be needed to ensure safe navigation
Identify the cause of the failure
Engine Room Actions
Call Chief Engineer
In the event of a Power Failure, also follow FE01 Power Failure checklist
Check main engine starting interlocks are not activated
Identify cause of failure
Check all required pumps and auxiliary machinery operating
Check appropriate ships side valves open
Restart main engine service systems
Restart main engine
Standby pumps to automatic mode
Check all systems are operating in a stable manner
Inform Bridge that power is restored
Monitor operations an an ongoing basis
Comments